Western Exterior Services, Inc.

Project

Seattle Christian Schools

Title

Missing Kick-Out Flashing

Primary Subject

Damage at Eave to Wall

Secondary Subject

New rainleader (downspout) direct to lower gutter

Secondary Subject

Counter Flashing at Stucco to Roof Transition

Secondary Subject

Good Life Cycle Planning

Secondary Subject

 

The step-flashings at the composition roofing did not originally include a kick-out to divert water out of the cladding assembly.

Gutters spilling onto the roof were dammed and new rain leaders were added to direct water into gutters. A removable counter-flashing with was applied at the transition of stucco to the roof to accommodate the shorter life cycle of roofing.

Roof Life Cycle:   20 years

Stucco Life Cycle:  50 years plus

Next Seattle Christian Schools Series

Close Window

Back To Top