Western Exterior Services, Inc.

Project

Village on the Green Phase I

Title

Kickout Flashing

Primary Subject

Kickout Flashing (missing)

Secondary Subject

Missing Kickout

Secondary Subject

Damage behind EIFS

Secondary Subject

Roof EIFS Transition Damage

Secondary Subject

Damage 4 Years Old

 

Water spilled from the gutter and entered at the lack of kickout flashing at the eave to wall transition

 

A simple flashing would have prevented the water entry by diverting the water into the gutter

 

The sheathing damage was severe, but the framing was not yet damaged

Repairs were made to the sheathing and preventive treatment was applied to the framing

 

The problem was typical throughout

The problem was typical throughout

 

The sheathing and the fascia required replacement

Next Village on The Green I Series

Close Window